How To Add Load Calcs Back To Analyze Tab

Step #1

Make sure the version of Revit you are editing is shut down. Open an instance of windows explorer & go to the following file path:

“%AppData%/Autodesk/Revit/Autodesk Revit (Revit Version)”

& find the Revit.ini file.

Step #2

Open this file using notepad or another text editor and under the “[Misc]” Section Add the following:

EnableHeatingAndCoolingLoads=1
EnableWeatherInLocation=1

Step #3

Save over the existing Revit.ini & you should now see the “Heating & Cooling Loads” button in the Analyze Tab.

,